Is representing a group of leading fire protection manufacturers as business partner suppliers to the Middle East, Mediterranean and Africa according to the territory area allowed for each brand.
Is specialized in providing the full engineering service for our fire Protection solutions starting from estimation, design, engineering up to full installation of the largest projects (fire fighting and fire alarm).
Is a specialized factory for various types of fire fighting manual product (Cabinets, fire hoses 'racks and reels’, Accessories... etc) The first UL LISTED, OEM FIKE (USA) gaseous filling station in Egypt for filling and refilling of HFC-227ea "FM200" gas.
The Kennedy Valve Company, located on East Water Street in Elmira, NY, is one of the world's largest manufacturers of FIRE HYDRANTS, CHECK VALVES, INDICATOR POSTS, GATE VALVES and BUTTERFLY VALVES. They are specializing in products for waterworks distribution, and fire protection system project.
Fire hydrants have been used in fire protection for over 100 years. AWWA C502 was developed in 1913 as a standard for the manufacture and use of dry barrel hydrants. Kennedy has established itself as a leader in the industry with manufacturing experience dating back to 1905. Many of the early hydrants are in use today.
Potter‘s quality-first attitude drives it to develop and manufacture the best and most reliable sprinkler monitoring, security, fire, and industrial control products.
The OSYSU is used to monitor the open position of an OS&Y (Outside screw and yoke) type gate valve. This device is Available in two models; the OSYSU-1, containing one set Of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount Conveniently to most OS&Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as Small as ½" (12,5mm).
The Potter Series Pressure Actuated Switches are designed for the Detection of a water flow condition in automatic fire sprinkler systems.
The Model ADPS is an Adjustable Dead band Pressure Switch with Independent set and reset points that are adjustable throughout The entire operating range of the switch. The minimum dead band (Minimum span between set and reset points) may be obtained at Any point in the operating range of the switch.
A change in pressure Greater than the high setting will reposition the switch mechanism to Open or close a single snap-action electrical switch.